Occlusafe™ (image)
Micro Balloons

Occlusafe™

Temporary Occlusion Balloon Catheter
  • Through Pressure Gradient Effect, Occlusafe™ as micro-balloon catheter, offers the ability to redistribute blood flow and access the microcirculation, leading to an increased accumulation of therapeutics into the target lesion with minimal off-target embolization.
  • This may be associated with improved clinical outcomes in challenging lesions.
Please contact your local representative for product details and catalogs.
A technical revolution in transarterial embolization
  • Through Pressure Gradient Effect, Occlusafe™ as micro-balloon catheter, offers the ability to redistribute blood flow and access the microcirculation, leading to an increased accumulation of therapeutics into the target lesion with minimal off-target embolization.
  • This may be associated with improved clinical outcomes in challenging lesions.
Standard Balloon inflation for complete occlusion (image)

Large lesion challenges
Large lesions only partially respond to current TACE treatment due to a poor embolic uptake. Multiple or combined treatments are required to reach a complete response.

 

Flow distribution
Through the pressure gradient effect, the balloon occlusion with Occlusafe™ offers the ability to redistribute blood flow and access the microvascular circulation, leading to an increased accumulation of therapeutics into the target lesion with minimal off-target embolization.

 

Access to microvascular circulation
The balloon occlusion with Occlusafe™ allows a better visualization for improved diagnosis and higher embolic uptake into the target lesion.

 

Excellence in navigability
Terumo excellence in lesion access technology guarantees a superb precision and accuracy in navigation through complex vessel anatomies.

 

Expected benefits from the micro balloon embolization (MBE)
・Greater tumor or radiological response
・Improved clinical outcome
・Better diagnosis thanks to more visibility
・Full protection against reflux

Occlusafe™ Product Introduction
Country Select
Please contact your regional representatives for more information on the products.Contact Us
Formulation No./ Model No. Balloon max diameter (mm) Balloon length(mm) Balloon injection volume(mL) Distal outer diameter (Fr.) Distal outer diameter (mm) Proximal outer diameter (Fr.) Proximal outer diameter (mm) Catheter O.D. / Tip (Fr) Usable catheter length (cm) Dead Volume Space / Main lumen (ml) Dead Volume Space / Infulation lumen (ml) Compatible GW (inch) Compatible GW (mm)
OB*T41140N 4.0 10 0.1 2.7 0.90 2.8 0.94 1.9 110 0.24 0.34 0.014 0.36
OB*T41140N 4.0 10 0.1 2.7 0.90 2.8 0.94 1.9 110 0.24 0.34 0.014 0.36
OB*T41140N 4.0 10 0.1 2.7 0.90 2.8 0.94 1.9 110 0.24 0.34 0.014 0.36
OB*T41140N 4.0 10 0.1 2.7 0.90 2.8 0.94 1.9 110 0.24 0.34 0.014 0.36
OB*T41140N 4.0 10 0.1 2.7 0.90 2.8 0.94 1.9 110 0.24 0.34 0.014 0.36
OB*T41140N 4.0 10 0.1 2.7 0.90 2.8 0.94 1.9 110 0.24 0.34 0.014 0.36
OB*T41140N 4.0 10 0.1 2.7 0.90 2.8 0.94 1.9 110 0.24 0.34 0.014 0.36
OB*T41340N 4.0 10 0.1 2.7 0.9 2.8 0.94 1.9 130 0.27 0.36 0.0140 0.36
OB*T41340N 4.0 10 0.1 2.7 0.9 2.8 0.94 1.9 130 0.27 0.36 0.0140 0.36
OB*T41340N 4.0 10 0.1 2.7 0.9 2.8 0.94 1.9 130 0.27 0.36 0.0140 0.36