Support Catheters
NaviCross™
Peripheral Support Catheter
NaviCross™ Support Catheter is dedicated to reaching and crossing complex lesions in challenging anatomy during femoro-popliteal and below-the-knee interventions.
Please contact your local representative for product details and catalogs.
Overview
Navigate complex procedures with confidence
NaviCross™ Support Catheter is dedicated to reaching and crossing complex lesions in challenging anatomy during femoro-popliteal and below-the-knee interventions.
Product Details
Reliable support for crossing lesion

Master your procedures with precise performance

Double-braided stainless steel
Engineered for optimal pushability and torque control for lesion crossing.

Telescoping capability
NaviCross™ 0.018" is designed to telescope through NaviCross 0.035".

Straight and angled tips
Tips allow access to vascular branches, including BTK collaterals.1

Tapered tip
Provides seamless guidewire-to-catheter transition, facilitating lesion access and crossing.

Robust wire support1
Smooth guidewire-to-catheter transition provides increased wire support, which may increase lesion crossability.
- Test protocol: This test measured the force of transmitted tip when the GW is pushed 5mm from the proximal end.

Strong pushability1
Double-braided stainless steel design runs the length of the device, giving optimal column strength without the disadvantage of distal to proximal tapering.
- Test protocol: This test measured the percentage of force that was transmitted to the distal tip when the catheter was pushed 3mm at the proximal end.

Great crossability1
Hydrophilic coating and tapered distal tip provide better crossability in simple or complex lesions.
- Test protocol: This test measured how far the catheter tip advanced when it was pushed in by 30mm.
Item Specifications
Country Select
Formulation No./ Model No. | Wire compatibility(inch) | Outer diameter(Fr.) | Catheter length(cm) | Tip shape | Markers |
---|---|---|---|---|---|
PN*NA18093HM | 0.018 | 2.6 | 90 | Angled | 3 (Tungsten) |
PN*NA18093HM | 0.018 | 2.6 | 90 | Angled | 3 (Tungsten) |
PN*NA18093HM | 0.018 | 2.6 | 90 | Angled | 3 (Tungsten) |
PN*NA18093HM | 0.018 | 2.6 | 90 | Angled | 3 (Tungsten) |
PN*NA18093HM | 0.018 | 2.6 | 90 | Angled | 3 (Tungsten) |
PN*NA18093HM | 0.018 | 2.6 | 90 | Angled | 3 (Tungsten) |
PN*NA180G3HM | 0.018 | 2.6 | 65 | Angled | 3 (Tungsten) |
PN*NA180G3HM | 0.018 | 2.6 | 65 | Angled | 3 (Tungsten) |
PN*NA180G3HM | 0.018 | 2.6 | 65 | Angled | 3 (Tungsten) |
PN*NA180G3HM | 0.018 | 2.6 | 65 | Angled | 3 (Tungsten) |