Accuforce™ (image)
PTCA Balloons

Accuforce™

PTCA Dilatation Catheter
  • The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability.
  • Accuforce™ is the latest generation of non-compliant PTCA balloons.
Please contact your local representative for product details and catalogs.
Force. Success. No Compromise
  • The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability.
  • Accuforce™ is the latest generation of non-compliant PTCA balloons.
Details of Accuforce™ (image)

Optimise (re) crossability and deliverability1

  • Soft balloon material and newly designed radiopaque markers improve flexibility.
  • Reinforcement of the guidewire exit port structure enhances the durability of the shaft and forces transmission from the proximal shaft to the distal tip for advanced pushability.
  • Low profile shaft and guidewire exit port enable the kissing balloon technique with a 6 Fr lumen guiding catheter.

 

Triple layer technology of Accuforce™ (image)

Provide impressive high-pressure resistance up to 22 atm

The innovative triple layer technology of Accuforce™ consists of:
  • Soft inner/outer elastomer layers offering resistance to high pressure from the inside and against damage to the outside.
  • Stronger middle layer in polyamide, which provides an additional and safer1 high pressure resistance required for severe calcified lesions.
Shorter and rounded balloon shoulders (image)

Be accurate in pre & post-dilatation

The additional elastomer layer compared to a traditional double layer balloon structure provides safer high-pressure dilatation1 with low compliance.2

Shorter and rounded balloon shoulders only target lesions and the stent for effective and focused dilatation as it is necessary for the Proximal Optimization Technique (POT) in bifurcations.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
  • Chapters
  • descriptions off, selected
  • captions off, selected
    Accuforce Product Introduction
    Country Select
    Please contact your regional representatives for more information on the products.Contact Us
    
    Formulation No./ Model No. Balloon max diameter (mm) Balloon length (mm) Usable catheter length (cm) Distal shaft diameter (Fr.) Distal shaft diameter (mm) Proximal shaft diameter (Fr.) Proximal shaft diameter (mm) Nominal pressure (atm) Nominal pressure (kPa) Rated burst pressure (atm) Rated burst pressure (kPa)
    DC-RM2506HSW 2.50 6 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2508HSW 2.50 8 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2512HHW 2.50 12 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2515HHW 2.50 15 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2520HHW 2.50 20 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2525HHW 2.50 25 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2530HHW 2.50 30 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2706HSW 2.75 6 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2708HSW 2.75 8 145 2.6 0.86 1.9 0.63 12 1216 22 2229
    DC-RM2712HHW 2.75 12 145 2.6 0.86 1.9 0.63 12 1216 22 2229